Main Menu (Mobile)- Block
- Our Research
-
Support Teams
- Overview
- Anatomy and Histology
- Cryo-Electron Microscopy
- Electron Microscopy
- Flow Cytometry
- Fly Facility
- Gene Targeting and Transgenics
- Immortalized Cell Line Culture
- Integrative Imaging
- Janelia Experimental Technology
- Media Prep
- Molecular Genomics
- Primary & iPS Cell Culture
- Project Pipeline Support
- Project Technical Resources
- Quantitative Genomics
- Scientific Computing Software
- Scientific Computing Systems
- Viral Tools
- Vivarium
- Open Science
- You + Janelia
- About Us
Main Menu - Block
- Overview
- Anatomy and Histology
- Cryo-Electron Microscopy
- Electron Microscopy
- Flow Cytometry
- Fly Facility
- Gene Targeting and Transgenics
- Immortalized Cell Line Culture
- Integrative Imaging
- Janelia Experimental Technology
- Media Prep
- Molecular Genomics
- Primary & iPS Cell Culture
- Project Pipeline Support
- Project Technical Resources
- Quantitative Genomics
- Scientific Computing Software
- Scientific Computing Systems
- Viral Tools
- Vivarium
Note: Research in this publication was not performed at Janelia.
Abstract
Fluorescence imaging of bulk-stained tissue is a popular technique for monitoring the activities in a large population of cells. However, a precise quantification of such experiments is often compromised by an ambiguity of background estimation. Although, in single-cell-staining experiments, background can be measured from a neighboring nonstained region, such a region often does not exist in bulk-stained tissue. Here we describe a novel method that overcomes this problem. In contrast to previous methods, we determined the background of a given region of interest (ROI) using the information contained in the temporal dynamics of its individual pixels. Since no information outside the ROI is needed, the method can be used regardless of the staining profile in the surrounding tissue. Moreover, we extend the method to deal with background inhomogeneities within a single ROI, a problem not yet solved by any of the currently available tools. We performed computer simulations to demonstrate the accuracy of our method and give example applications in ratiometric calcium imaging of bulk-stained olfactory bulb slices. Converting the fluorescence signals into [Ca2+] gives resting values consistent with earlier single-cell staining results, and odorant-induced [Ca2+] transients can be quantitatively compared in different cells. Using these examples we show that inaccurate background subtraction introduces large errors (easily in the range of 100%) in the assessment of both resting [Ca2+] and [Ca2+] dynamics. The proposed method allows us to avoid such errors.