Filter
Associated Lab
Publication Date
- June 28, 2008 (1) Apply June 28, 2008 filter
- June 26, 2008 (1) Apply June 26, 2008 filter
- June 24, 2008 (1) Apply June 24, 2008 filter
- June 11, 2008 (1) Apply June 11, 2008 filter
- June 10, 2008 (2) Apply June 10, 2008 filter
- June 6, 2008 (1) Apply June 6, 2008 filter
- June 4, 2008 (1) Apply June 4, 2008 filter
- June 1, 2008 (5) Apply June 1, 2008 filter
- Remove June 2008 filter June 2008
- Remove 2008 filter 2008
Type of Publication
13 Publications
Showing 11-13 of 13 resultsA new type of wide-field fluorescence microscopy is described, which produces 100-nm-scale spatial resolution in all three dimensions, by using structured illumination in a microscope that has two opposing objective lenses. Illumination light is split by a grating and a beam splitter into six mutually coherent beams, three of which enter the specimen through each objective lens. The resulting illumination intensity pattern contains high spatial frequency components both axially and laterally. In addition, the emission is collected by both objective lenses coherently, and combined interferometrically on a single camera, resulting in a detection transfer function with axially extended support. These two effects combine to produce near-isotropic resolution. Experimental images of test samples and biological specimens confirm the theoretical predictions.
Juvenile hormone (JH) is a key hormone in regulation of the insect’s life history, both in maintaining the larval state during molts and in directing reproductive maturation. This short review highlights the recent papers of the past year that lend new insight into the role of this hormone in the larva and the mechanisms whereby it achieves this role.
Structured illumination microscopy is a method that can increase the spatial resolution of wide-field fluorescence microscopy beyond its classical limit by using spatially structured illumination light. Here we describe how this method can be applied in three dimensions to double the axial as well as the lateral resolution, with true optical sectioning. A grating is used to generate three mutually coherent light beams, which interfere in the specimen to form an illumination pattern that varies both laterally and axially. The spatially structured excitation intensity causes normally unreachable high-resolution information to become encoded into the observed images through spatial frequency mixing. This new information is computationally extracted and used to generate a three-dimensional reconstruction with twice as high resolution, in all three dimensions, as is possible in a conventional wide-field microscope. The method has been demonstrated on both test objects and biological specimens, and has produced the first light microscopy images of the synaptonemal complex in which the lateral elements are clearly resolved.